TECHNICAL DATA
DIMENSIONS
Height Width Depth
Height to hotplate 907mm (nominal) 498mm 600 mm
(to front of
door panel)
Space for fixing at hotplate level 2mm minimum clearance
Minimum space above hotplate 787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
Space for fixing above hotplate level See important note "Location of Appliance", page 33.
Weight of appliance 48.4kg.
Minimum distance from rear wall 1mm
CONNECTIONS
Gas Rear left hand side of appliance at hotplate level.
Rc½ (½" B.S.P. female).
Electric None
IGNITION
Spark generator APCO 6BG 6893
Battery 1.5 Volt AA size
GRILL
Natural Gas L.P. Gas
Heat Input 3.3kW (11263 Btu/h)3.0kW (215g/h)
Injector Marking 138 88
HOTPLATE
Natural Gas
R.H.F. R.H.R. L.H.R. L.H.F
Heat Input 1.0kW 2.0kW 2.0kW 2.8kW
(3412 Btu/h) (6824 Btu/h) (6824 Btu/h) (9554 Btu/h)
Injector Marking 079 104 104 130
L.P.Gas
Heat Input 1.0kW 2.0kW 2.0kW 2.7kW
(71.8 g/h) (143.7 g/h) (143.7 g/h) (194.0 g/h)
Injector Marking 051 072 072 083