FITTING THE STABILITY BRACKET
It is recommended that if the appliance is to be installed with a flexible supply pipe, a stability bracket (SK.4729.A)
is fitted, and is available from your supplier (see Important Safety Requirements). These instructions should be
read in conjunction with the leaflet packed with the stability bracket.
1. Place the appliance in its intended position and level appliance.
2. Mark off 300mm from the left hand side of the appliance as shown in dimension 'A' Fig.4a. This is the centre
line of the fixing bracket.
3. Draw a line from the front edge of the feet (see Fig.4a) and remove appliance from its position. Mark off
dimension 'B' (see Fig.4a) back from this line on the centre line of the bracket to locate the front edge of the
lower bracket. Fix lower bracket (with two fixing holes) to the floor then measure the height from floor level to
engagement edge on back of appliance, dimension 'C' of Fig. 4b.
4. Assemble upper bracket to lower bracket so that the underside of bracket is dimension 'C' + 3mm above floor
level. (See Fig. 4b)
Reposition appliance and check that top bracket engages into appliance back as shown in Fig. 4b.
INSTALLATION INSTRUCTIONS
(C)
100mm
487mm (B)
(
A
)
300mm
Fig.4a.
Fig.4b.