TECHNICAL DATA
DIMENSIONS
Height Width Depth
Height to hotplate 900mm (nominal) 554mm (nominal) 600 mm
(to front of
door panel)
Space for fixing at hotplate level 2mm minimum clearance
Space for fixing above hotplate level See important note "Location of Appliance", page 40.
Minimum space above hotplate 787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
Weight of appliance 61kg.
Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel).
CONNECTIONS
Gas Rear left hand side of appliance at hotplate level.
Rc½ (½" B.S.P. female).
Electric None
IGNITION
Battery 1.5 Volt AA size
GRILL
Natural Gas
L.P. Gas
Heat Input 2.7kW (9215 Btu/h) 2.45kW (176g/h)
Injector Marking 121 078
HOTPLATE
Natural Gas
R.H.F. R.H.R. L.H.R. L.H.F
Heat Input 1.0kW 2.0kW 2.0kW 2.8kW
(3412 Btu/h) (6824 Btu/h ( 6824 Btu/h) (9554 Btu/h)
Injector Marking 079 104 104 130
L.P.Gas
Heat Input 1.0kW 2.0kW 2.0kW 2.7kW
(71.8 g/h) (143.7 g/h) (143.7 g/h) (194.0 g/h)
Injector Marking 051 072 072 083